Reply within 24 hours · speak with an engineer
Huanghai
RCZ-6N Intelligent Dissolution Tester – Pharma Lab Equipment for Dissolution Testing
RCZ-6N Intelligent Dissolution Tester – Pharma Lab Equipment for Dissolution Testing
Distributor & agent pricing available on request. Equipping a full QC lab? Ask about multi-unit bundle pricing.
Sale Sold outSince 1978 · Nearly 1,000 clients in 30+ countries · Used at Sinopharm, Fosun Pharma and Shanghai Pharma Group About Huanghai →
At a glance: The Huanghai RCZ-6N is a 6-vessel intelligent dissolution tester from Huanghai Pharmaceutical Instruments (Shanghai, since 1978), sized to run a full six-unit USP <711> stage in one go. Vessels and shafts centre automatically, heating can be scheduled, two 150 ml replenishment vessels can be fitted, and built-in data integrity features record every run. It runs USP Apparatus 1 (basket) and 2 (paddle) per USP <711>, ChP 0931 and Ph. Eur. 2.9.3.
What the Huanghai RCZ-6N does for your lab
- One run, one full stage. Six vessels match the six units of a USP <711> stage, so a complete stage runs at once.
- Automatic vessel and shaft centring. Less set-up time and fewer alignment differences between runs.
- Two 150 ml replenishment vessels. Fresh medium to replace what each sampling withdraws can be kept at the instrument.
- Scheduled pre-heating. Set a start time and the bath is at temperature when you arrive; a 24-hour reservation timer covers the working day.
- Protected, calibrated temperature. Dual over-temperature protection and a temperature calibration function protect the sample and keep readings traceable.
- Sample information on the instrument. Sample details are stored for reuse, so repeat tests start faster.
- Built-in data integrity. Password login, three permission levels (Operator, Supervisor, System Administrator), audit trail, data backup and USB export or printing keep every run traceable. The instrument is designed with features that support a 21 CFR Part 11 workflow.
- Quick-connect water circuit. Water-circulation pipework with medical-grade quick connectors makes servicing and changeover easier.
Watch the operation demo
Huanghai RCZ-6N dissolution tester: operation demo
Specifications
| Parameter | Specification |
|---|---|
| Model | RCZ-6N |
| Test stations | 6 vessels |
| Apparatus | USP Apparatus 1 (basket) / 2 (paddle) |
| Speed | 10–300 rpm, accuracy ≤±1% |
| Temperature | Room temperature to 45.0 °C, control accuracy ≤±0.3 °C |
| Swing amplitude | Paddle ≤0.5 mm, basket ≤1.0 mm |
| Shaft-to-vessel alignment | ≤1.0 mm |
| Sampling cycle points | ≤100 |
| Maximum test time | ≤999 h 59 min 59 s |
| Replenishment vessels | 2 × 150 ml |
| Power supply | AC 220 V ±10%, 50 Hz |
📄 Download User Manual
You can download the full user manual of the RCZ-6N Dissolution Tester below:
📥 Click here to download RCZ-6N User Manual (PDF)
Frequently Asked Questions
Which pharmacopoeia methods does this dissolution tester follow?
USP <711> Apparatus 1 (basket) and Apparatus 2 (paddle), ChP 0931 and Ph. Eur. 2.9.3. The 10–300 RPM speed range covers the usual 50 RPM paddle and 100 RPM basket settings.
How many vessels does a QC lab need?
USP <711> tests 6 units per stage, so 6 vessels (RCZ-6N) run a full stage at once.
Does it support data-integrity requirements?
Yes. It has 3-level user management (Operator / Supervisor / System Administrator), an audit trail recording operator, date-time and event type, test data query, USB export and RS232 printing. It is designed with features that support a 21 CFR Part 11 workflow.
What options are available for light-sensitive drugs?
Amber glass vessels of the same 1,000 ml size can replace clear vessels for photosensitive APIs.
What are the two 150 ml vessels for?
They are replenishment vessels: the RCZ-6N can hold two of them, so fresh medium to replace the volume withdrawn at sampling can be kept at the instrument.
Does the Huanghai RCZ-6N centre the vessels automatically?
Yes. Vessels and shafts centre automatically, which makes set-up faster and more repeatable.
Can I schedule heating in advance?
Yes. A reservation timer of up to 24 hours starts heating at the time you set, so the bath is ready when you arrive.
This Dissolution Tester is CE certified under two EU directives:
- Machinery Directive 2006/42/EC — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019
- EMC Directive 2014/30/EU — EN IEC 61326-1:2021
Related: how to calibrate a dissolution tester, step by step, in our dissolution tester calibration guide.