How to choose a TOC analyzer for pharmaceutical water
Total organic carbon (TOC) is the pharmacopoeial indicator of organic contamination in purified water and water for injection (WFI). The TOC-1500 uses UV photocatalytic oxidation, so it needs no acid reagent, catalyst or carrier gas. It measures 1–1,500 ppb with a 1 ppb detection limit in under 3 minutes per test, at the bench or as an online monitor, and complies with the ChP 2020 TOC method, USP <643> and Ph. Eur. 2.2.44.
Model comparison
| Mode | Use | Range | Sampling | Data |
|---|---|---|---|---|
| TOC-1500 benchtop (offline) | Grab samples of purified water, WFI and cleaning-validation samples | 1–1,500 ppb | Automatic micro-volume sampling; optional 20-position autosampler | 8 GB storage, USB export, Bluetooth printer |
| TOC-1500 online | Continuous monitoring of a pharmaceutical water system | 1–1,500 ppb | Online monitoring interface; switchable from offline mode | Alarm when the upper limit is exceeded |
How to choose
- Sample type: TOC-1500 is built for low-TOC water (below 1.5 ppm) with conductivity ≤1 μS/cm at 25 °C, such as purified water, pharmaceutical deionized water and WFI.
- Lab or loop: test grab samples at the bench, or switch to online mode for continuous monitoring of the water system.
- Many samples: add the optional 20-position autosampler for unattended, continuous testing.
- Running costs: UV photocatalytic oxidation avoids acid reagents, catalysts and carrier gas.
- Performance: maximum allowable error ±5%, repeatability ≤3%, sample temperature 1–95 °C.
Pharmacopoeia and compliance
Complies with the ChP 2020 total organic carbon method, USP <643> system suitability requirements and Ph. Eur. 2.2.44. CE certified. Password-protected access, a searchable test history (8 GB storage) and USB export support record keeping.
Frequently asked questions
What does a TOC analyzer measure?
The total organic carbon content of water, in ppb. In pharmaceutical plants it is used to check purified water and WFI for organic contamination and to verify cleaning.
Which pharmacopoeia chapters apply?
TOC-1500 complies with the ChP 2020 total organic carbon method, USP <643> system suitability requirements and Ph. Eur. 2.2.44.
Does the TOC-1500 need reagents or gas?
No. UV photocatalytic oxidation needs no acid reagent, catalyst or carrier gas.
How fast is a test?
A single test takes under 3 minutes, with a range of 1–1,500 ppb and a 1 ppb detection limit.
Can it be used for cleaning validation?
Yes. Cleaning-validation verification in pharmaceutical and biochemical manufacturing is one of its applications, alongside purified water, deionized water and WFI testing.