{"product_id":"lc210-hplc-system","title":"LC210 HPLC System — High-Performance Liquid Chromatography Platform","description":"\u003c!-- TITLE: LC210 HPLC System — High-Performance Liquid Chromatography Platform --\u003e\n\u003c!-- Drafted 2026-07-21 from Vault\/01-Knowledge\/HPLC\/LC210_HPLC_Brochure_Extract.md (source: 仪电分析-中文样本-整本2501.pdf P56). EN only, DRAFT. --\u003e\n\n\u003ch2\u003eLC210 HPLC System — High-Performance Liquid Chromatography Platform\u003c\/h2\u003e\n\n\u003cp\u003eThe LC210 HPLC System is a high-performance liquid chromatography platform built around a stable reciprocating series-flow constant-flow pump, a PID-controlled column thermostat, and a UV detector, operated through a 7\" color touchscreen with built-in workstation software. Available in a single-pump configuration for high-precision isocratic delivery, or a dual-pump configuration that adds binary high-pressure gradient elution with in-line mixing for uniform mobile-phase blending.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-sensitivity detector with a fluid-dynamics-optimized heat-dissipation channel and a thermally isolated, insulated design that suppresses the effect of ambient temperature swings, plus strong electromagnetic shielding\u003c\/li\u003e\n  \u003cli\u003eHighly integrated microprocessor and multi-bus architecture, low-drift low-noise high-sensitivity preamplifier, 24-bit precision A\/D conversion\u003c\/li\u003e\n  \u003cli\u003eStable-flow reciprocating series constant-flow pump rated for high pressure, easy to maintain; a high-performance buffer smooths pulsation for precise, stable flow — supports high-precision isocratic delivery, or binary high-pressure gradient elution with a mixer for uniform blending of different mobile phases\u003c\/li\u003e\n  \u003cli\u003eKey wear parts (e.g. plunger rod) support in-line cleaning to extend seal life; process-control monitoring flags blockages and leaks\u003c\/li\u003e\n  \u003cli\u003e7\" color touchscreen with built-in workstation software (audit-trail capability available as an add-on), bidirectional operation\u003c\/li\u003e\n  \u003cli\u003ePrecision-machined on CNC equipment for consistent build quality, with imported core components and accessories\u003c\/li\u003e\n  \u003cli\u003eLong-life imported deuterium lamp with a dedicated lamp power supply; modular flow-cell design for easy disassembly and cleaning; manual or automatic injector available\u003c\/li\u003e\n  \u003cli\u003eTime-programmed wavelength detection\u003c\/li\u003e\n  \u003cli\u003ePID auto-tuning algorithm for precise column-oven temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSystem Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eColumn Thermostat:\u003c\/strong\u003e Control accuracy ±1°C; range ambient+10°C to 80°C (1°C increments); temperature stability ≤0.2°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure Pump:\u003c\/strong\u003e Flow-rate setting range 0.001–9.999 mL\/min; flow stability ≤0.3%; maximum output pressure 45 MPa\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUV Detector:\u003c\/strong\u003e Wavelength range 190–700 nm; wavelength accuracy ±1 nm; wavelength repeatability ≤0.2 nm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBaseline Noise:\u003c\/strong\u003e ≤5×10⁻⁶ AU (254 nm, empty cell); ≤9×10⁻⁶ AU (254 nm, methanol mobile phase)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBaseline Drift:\u003c\/strong\u003e ≤5×10⁻⁵ AU\/h (254 nm, empty cell); ≤1×10⁻⁴ AU\/h (254 nm, methanol mobile phase)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Detectable Concentration:\u003c\/strong\u003e ≤5×10⁻⁹ g\/mL (sample: naphthalene; carrier: methanol; 254 nm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e Qualitative ≤0.3% (manual injection); Quantitative ≤0.9% (manual injection)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 220V±22V, 50Hz±0.5Hz, 400W\u003c\/p\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cp\u003eCE certified.\u003c\/p\u003e\n\n\u003c!-- FAQ --\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What's the difference between the single-pump and dual-pump LC210?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The single-pump configuration runs high-precision isocratic delivery. The dual-pump configuration adds a second pump for binary high-pressure gradient elution, with an in-line mixer for uniform blending of different mobile phases. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss which configuration fits your method.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What injector options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The LC210 supports either a manual injector or an automatic injector, selectable based on your lab's throughput needs. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e for configuration options.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the LC210 support audit trail functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The built-in workstation software supports 7\" touchscreen bidirectional operation, with audit-trail capability available as an add-on. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss documentation for your regulatory environment.\u003c\/p\u003e","brand":"Huanghai","offers":[{"title":"Single Pump","offer_id":46231937187897,"sku":"LC210-SP","price":11643.0,"currency_code":"USD","in_stock":true},{"title":"Dual Pump","offer_id":46231937220665,"sku":"LC210-DP","price":15197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LC210_HPLC_System.jpg?v=1784641252","url":"https:\/\/drugmachines.com\/products\/lc210-hplc-system","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}